Heat pump Rhoss

83 / 100

An Italian Manufacturer of  Heat Pump Rhoss  and Chiller Rhoss 

Rhoss  chiller  for S.p.a. a socio unico, soggetta a direzione e coordinamento di NIBE Industrier AB (publ)
N. iscr. Reg. Impr. UD 01142230299 – Capitale sociale: 12.020.000,00 (i.v)

Imported and distributed by Seilar CN Vietnam JSC

Two-section reversible air-water heat pumps. Range with hermetic rotary DC Inverter compressors and R32 refrigerant gas.

 

COMMERCIAL  HEAT PUMP RHOSS

  • Construction features

    Compressor: hermetic, rotary scroll type, complete with thermal protection and casing heater. 3 capacity steps with high efficiency at partial loads for models 245-265.
    Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater and water flow differential pressure switch.
    Air side heat exchanger: finned coil with copper pipes and aluminum fins, complete with protection grilles.
    Fan: external rotor helical type electric fan equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan speed regulation.
    Control: microprocessor electronic control with Adaptive Function Plus logic.
    Structure: made of galvanized and painted sheet steel.
    The unit is also complete with:

    Master/Slave control up to 4 units in parallel;  Commercial heat pump model POKER THAETY 234 H.T.
    clock board.

    Models

    TCAEY: unit designed for cooling only.
    THAEY: heat pump  Rhoss  unit.

    PUMP set-up

    Pump unit complete circulator, single or double electric pump, including an automatic actuation pump in standby (mod. 245-265), expansion tank, air bleed valves, safety valve and water side pressure gauge.

    TANK&PUMP set up
    Pump unit complete inertial buffer tank, circulator, single or double electric pump, including an automatic actuation pump in standby (mod. 245-265), expansion tank, air bleed valves, safety valve and water side pressure gauge.

    Factory fitted accessories

    Soft-start device.
    Silenced set up.
    15% de super heater.
    100% heat recovery unit.
    Condensing control with fans with EC motor.

    Refrigerant circuit high and low pressure gauges (mod. 245-265).
    Buffer tank antifreeze heater.
    Electric pump antifreeze heater (mod. 245-265).
    Forced limit of power consumption.
    Refrigerant leak detector.
    Digital input for double set-point
    4-20 mA analogue signal for shifting set-point.
    Energy parameter measuring device.
    Low water set-point temperature.
    Pre-painted copper/coils or copper/copper coils.

    Separately supplied accessories

    • Outdoor air temperature probe for set-point compensation.
    • Additional electrical resistance for heat pump, managed by regulation.
    • Rubber anti-vibration mounts.
    • Water filter.
    • Remote keypad with display.
    • Interfaces for serial communication with other devices.
    • Serial converter (RS485/USB).
    • Rhoss supervisors for unit monitoring and remote management.

    REFERENCES

  • Construction features of heat pump  Rhoss
  • MHAITI outdoor unit – Heat Pump Rhoss
  • • Compressor: hermetic, twin rotary DC Inverter with steam injection, complete with thermal protection and casing heater
    • Expansion valve: electronic.
    • Cooling circuit with economy
    • Air side heat exchanger: finned coil with copper pipes and aluminum-manganese fins with Golden Fin anti-corrosion treatment in epoxy resin and hydrophilic treatment, complete with protection grilles.
    • Fan: axial type impeller with DC brushless motors, equipped with internal thermal protection, accident protection grilles and proportional electronic device for continuous fan rotation speed regulation.
    • Structure: made of galvanized and painted steel plate RAL9002, complete with condensate drain pan and unit base antifreeze heater.
  • IUB indoor unit – Heat Pump Rhoss
  • Hydronic module for wall mounting installation:
    • Structure: made of galvanized and painted steel plate.
    • Water side heat exchanger: adequately insulated stainless steel plates, complete with antifreeze heater.
    • Pump unit complete with: EC circulator, automatic air vent valve, safety valve, flow switch, expansion tank, pressure gauge, water filter.
    • 3-way valve for the production of domestic hot water.
    • Supplementary electrical resistance, system side.
    • Control: microprocessor electronic control with touch-screen panel for integrated management of the heat pump and the heating system, according to the various requirements relating to the use of the energy sources:
  • – 3-way diverter valve management for production of domestic hot water.
    – Rapid heating function for domestic hot water.
    – Anti-legionella cycle function, with activation timer.
    – Auxiliary or supplementary heat source management.
    – Operation in silent mode with timer.
    – Weekly and daily time bands.
    – Holiday mode and antifreeze function.
    – Power consumption limiting function.
    – 2-way on/off valve management for shutting off a part of the system, in heating or cooling mode.
    – Management through room thermostat, as an alternative to the touch-screen panel.
    – Unit activation from external contact (remote ON/OFF)
    • Unit  Heat Pump Rhoss complete with:
    – Outdoor temperature probe for set-point compensation.
    – Remote ambient air temperature probe, for managing the unit according to the ambient set-point.
    – Water temperature probe for domestic hot water tank (20 m).
    – Communication cable between outdoor and indoor units.
    • RS485 interface for serial communication with other devices (Modbus RTU protocol).
    • iOS and Android APP for managing the unit via smartphone and tablet.
  • Version
  • T – High efficiency.
  • Models
  • MHAITI+USB: 2-section air-water heat pump.
  • Separately supplied accessories
  • Commercial heat pump model POKER THAETY 234 H.T.
  • KSA – Rubber anti-vibration mounts.
  • POKER

    THAETY 234 H.T.

    COOLING CAPACITY: 28.8÷115.2 KW

    HEATING CAPACITY: 33.8÷135.2 KW

    WEBCODE: PK001

    PRODUCT BENEFITS

     Modular range: up to 4 units may be combined

     Total system redundancy with multiple modules installed

     Cascade management including DHW with multiple modules installed

     Hot water production from -20°C to 40°C outdoor air

     Temperature of the produced water up to 60°C

  • More information  may needed:
  • Rhoss presents EasyPACK ECO EXP, air cooled Multipurpose units, with scroll compressors and low GWP R454B refrigerant.
  • The new product range is available in 6 sizes and covers a cooling capacity from 70 up to 135 kW, in the following versions:
    • T version – High efficiency (A class in heating mode)
    • Q version – Super silent (A class in heating mode)
  • These new models features:
  • • Optimized design with R454B low GWP ecological gas.
     Double refrigerant circuits configuration for all sizes, with two optimized structures.
    • High energy efficiency over the Ecodesign directive threshold.
    • Extended operating limits with hot water production up to 60°C in winter mode.
    • VPF_R control (Variable Primary Flow by Rhoss).
    • SIR – Rhoss Integrated Sequencer.
    • Wide range of accessories to meet every customer need.
  • Thanks to the introduction of this new product range, Rhoss extends the Multi-purpose units with low GWP gas R454B offer.
  • EasyPACK ECO EXP, WinPACK ECO EXP and WinPOWER ECO EXP product ranges cover a capacity from 70 up to 640 kW and guarantee high efficiencies in all working conditions in an ecological and sustainable way.
  • Tag: Chiller Rhoss